期刊名称:Journal of Sustainable Development of Energy, Water and Environment Systems
电子版ISSN:1848-9257
出版年度:2017
卷号:5
期号:4
页码:560-578
DOI:10.13044/j.sdewes.d5.0167
语种:English
出版社:International Centre for Sustainable Developmen of Energy, Water and Environment Systems
摘要:This paper presents a real industrial example in which the steam utility network of a refinery is modelled in order to evaluate potential Heat Integration retrofits proposed for the site. A refinery, typically, has flexibility to optimize the operating strategy for the steam system depending on the operation of the main processes. This paper presents a few examples of Heat Integration retrofit measures from a case study of a large oil refinery. In order to evaluate expected changes in fuel and electricity imports to the refinery after implementation of the proposed retrofits, a steam system model has been developed. The steam system model has been tested and validated with steady state data from three different operating scenarios and can be used to evaluate how changes to steam balances at different pressure levels would affect overall steam balances, generation of shaft power in turbines, and the consumption of fuel gas.