期刊名称:IOP Conference Series: Earth and Environmental Science
印刷版ISSN:1755-1307
电子版ISSN:1755-1315
出版年度:2018
卷号:108
期号:5
页码:052100
DOI:10.1088/1755-1315/108/5/052100
语种:English
出版社:IOP Publishing
摘要:Optimization experiment of SCR denitrification technologies on a 300MW unit was conducted. Adjustment of ammonia injection quantity of corresponding AIG was conducted after measuring the SCR export NOx concentration field in 250MW load, the distribution uniformity of NOx volume fraction at the outlet of both reactor A and B was improved significantly, where the relative standard deviation of NOx reduced respectively from 29.83% to 13.01% and 24.54% to 9.26%, simultaneously, the amount of ammonia escape of A, B reactor decrease respectively by 24.76%, 19.45%. The results of optimization experiment show that, optimal adjustment can improve the NOx concentration distribution, reduce the amount of ammonia escape in a certain extent, and judge whether the catalytic activity of the regional catalyzer is in good condition. As to the area where catalyst is ineffective, the effect of optimization experiment is limited, the catalyzer should be the timely replacement, so as to better protect downstream equipment.