首页    期刊浏览 2024年09月12日 星期四
登录注册

文章基本信息

  • 标题:Experimental Analysis of the Thermal Performance of a Sunspace Attached to a House with a Central Air Conditioning System
  • 本地全文:下载
  • 作者:Ma, Qingsong ; Fukuda, Hiroatsu ; Lee, Myonghyang
  • 期刊名称:Sustainability
  • 印刷版ISSN:2071-1050
  • 出版年度:2018
  • 卷号:10
  • 期号:5
  • 页码:1-17
  • 出版社:MDPI, Open Access Journal
  • 摘要:In this paper, the thermal performance of a sunspace attached to a house with a central air conditioning system was experimentally investigated. The house with a south-facing sunspace is located in Miyazaki, Japan, where heating is required in winter. In order to reduce the heating energy in winter, the hot air from the attached sunspace is sent to the central air conditioning room, from where it is then distributed and stored throughout the house by way of air circulation. Only when the temperature in the sunspace exceeds 24 °C is the hot air in the sunspace sent to the central air conditioning room. The air circulation between the attached sunspace and central air conditioning room is 500 m 3 /h. The temperature of the attached sunspace and each room were measured. The results showed that a house with a sunspace can save about 12.2% of energy compared to a house without a sunspace.
  • 关键词:thermal performance; sunspace; experiment
国家哲学社会科学文献中心版权所有