摘要:With the development of L X-ray fluorescence (LXRF) to measure cortical bone lead directly, safely, rapidly, and noninvasively, the present study was undertaken to a) evaluate LXRF as a possible replacement for the CaNa2EDTA test; b) quantify lead in tibial cortical bones of mildly to moderately lead-toxic children before treatment; and c) quantify lead in tibial cortical bones of lead-toxic children sequentially following one to two courses of chelation therapy. The clinical research design was based upon a longitudinal assessment of 59 untreated lead-toxic children. At enrollment, if the blood lead (PbB) was 25 to 55 micrograms/dL and the erythrocyte protoporphyrin (EP) concentration was greater than or equal to 35 micrograms/dL, LXRF measurement of tibial bone lead was carried out. One day later, each child underwent a CaNa2EDTA provocative test. If this test was positive, lead-toxic children were admitted to the hospital for 5 days of CaNa2EDTA therapy. These tests were repeated 6 weeks and 6 months after enrollment. Abatement of lead paint hazards was achieved in most apartments by the time of initial hospital discharge. The LXRF instrument consists of a low energy X-ray generator with a silver anode, a lithium-doped silicon detector, a polarizer of incident photons, and a multichannel X-ray analyzer. Partially polarized photons are directed at the subcutaneous, medial mid-tibial cortical bone. The LXRF spectrum, measured 90 degrees from the incident beam, reveals a peak in the 10.5 KeV region, which represents the lead L alpha line.(ABSTRACT TRUNCATED AT 250 WORDS) Full text Full text is available as a scanned copy of the original print version. Get a printable copy (PDF file) of the complete article (1.1M), or click on a page image below to browse page by page. Links to PubMed are also available for Selected References . 271 272 273 274 275 276 277