首页    期刊浏览 2025年06月17日 星期二
登录注册

文章基本信息

  • 标题:Formation, occurrence and analysis of polychlorinated dibenzofurans, dioxins and related compounds.
  • 作者:H R Buser
  • 期刊名称:Environmental Health Perspectives
  • 印刷版ISSN:0091-6765
  • 电子版ISSN:1552-9924
  • 出版年度:1985
  • 卷号:60
  • 页码:259
  • 语种:English
  • 出版社:OCR Subscription Services Inc
  • 摘要:In several accidents (fires, explosions) involving electrical systems containing polychlorinated biphenyls (PCBs) or benzenes (PCBZs), the formation of polychlorinated tricyclic aromatic compounds such as polychlorinated dibenzofurans (PCDFs), dibenzo-p-dioxins (PCDDs) and biphenylenes (PCBPs) was observed. These findings were not surprising in light of our previous studies on the formation of PCDFs and PCDDs from the thermolysis (500-750 degrees C in presence of air) of PCBs or PCBZs. In these experiments we identified three main and a fourth minor reaction pathway leading to PCDFs from PCBs. The three main reactions involved the loss of ortho-Cl2, and the losses of ortho-HCl with and without a 2,3-chlorine shift. The fourth, minor reaction route found with some PCBs, involved the loss of ortho-H2. These reaction pathways were intramolecular cyclizations via oxidation to phenolic compounds. Thermolysis of commercial PCBs (Aroclor 1254 and 1260) yielded the same PCDF isomers as expected from the main PCB components via these four reaction pathways; the isomers formed included the toxic 2,3,7,8-substituted tetra-, penta- and hexa-CDFs. Thermolysis of PCBZs involved complex condensation reactions with multiple rearrangements leading to PCDFs as well as PCDDs. Again oxidation to phenolic products was involved but the reaction routes are not yet fully elucidated. The results of samples from transformer and capacitor accident sites showed very complex PCDF mixtures with 2,3,7,8-substituted isomers as main components and originating from the PCBs in the transformer liquid. The unusual presence of PCDDs in samples from the Binghamton accident originates from PCBZs present in transformer fluid of that specific installation, thus confirming our previous thermolysis findings.(ABSTRACT TRUNCATED AT 250 WORDS) Full text Full text is available as a scanned copy of the original print version. Get a printable copy (PDF file) of the complete article (1.4M), or click on a page image below to browse page by page. Links to PubMed are also available for Selected References . 259 260 261 262 263 264 265 266 267
Loading...
联系我们|关于我们|网站声明
国家哲学社会科学文献中心版权所有