期刊名称:International Journal of Electrical and Computer Engineering
电子版ISSN:2088-8708
出版年度:2018
卷号:8
期号:2
页码:888-899
DOI:10.11591/ijece.v8i2.pp888-899
语种:English
出版社:Institute of Advanced Engineering and Science (IAES)
摘要:This paper describes the importance of FACTS devices; it presents the outcome of the study of its reflectance on the performance of power system networks. It seeks to increase and guarantee the fact and accuracy of response systems under disturbance conditions when the phase measurement units are introduced as Real-Time Measurement (RTM) stations. This paper also describes the importance of FACTS devices. The combination of FACTS devices and PMUs is presented to increase the controllability performance of power systems. This paper demonstrates how PMUs measure voltage, current and their angles. It provides, through a communication link, a Phase Angle Data Concentrator (PDC) to make an appropriate decision to correct the power system state using the FACTS device (TCSC). We utilized the Graph-Theoretic Algorithm to optimize the number and location of PMUs. The technique proposed was tested on the Iraqi National Super Grid’s 24bus network, Diyala City’s regional 10bus network and the 14bus IEEE standard test system. The MATLAB/PSAT package was utilized for the simulation of results. It is evident that our proposed algorithm and technique achieved the purpose of this paper as confirmed by the level of accuracy of the results obtained from most of the cases tested.
其他摘要:This paper describes the importance of FACTS devices; it presents the outcome of the study of its reflectance on the performance of power system networks. It seeks to increase and guarantee the fact and accuracy of response systems under disturbance conditions when the phase measurement units are introduced as Real-Time Measurement (RTM) stations. This paper also describes the importance of FACTS devices. The combination of FACTS devices and PMUs is presented to increase the controllability performance of power systems. This paper demonstrates how PMUs measure voltage, current and their angles. It provides, through a communication link, a Phase Angle Data Concentrator (PDC) to make an appropriate decision to correct the power system state using the FACTS device (TCSC). We utilized the Graph-Theoretic Algorithm to optimize the number and location of PMUs. The technique proposed was tested on the Iraqi National Super Grid’s 24bus network, Diyala City’s regional 10bus network and the 14bus IEEE standard test system. The MATLAB/PSAT package was utilized for the simulation of results. It is evident that our proposed algorithm and technique achieved the purpose of this paper as confirmed by the level of accuracy of the results obtained from most of the cases tested.
关键词:Electrical (Power);Instrumentation and Control;;Phase Measurement Units;power system control; Real Time Measurement station (RTM); Diyala City network; FACTS devices