  • 标题:Performance of Governor System on Minimizing Frequency Fluctuations with Wind Power Generation
  • 作者:Dr. Md. Rafiqul Islam Sheikh ; Md. Mejbaul Haque ; M.A. Hossain
  • 期刊名称:International Journal of Electrical and Computer Engineering
  • 电子版ISSN:2088-8708
  • 出版年度:2011
  • 卷号:2
  • 期号:1
  • 页码:46-56
  • 语种:English
  • 出版社:Institute of Advanced Engineering and Science (IAES)
  • 摘要:As wind turbine output is proportional to the cube of wind speed, the wind turbine generator output fluctuates due to wind speed variations. Hence, if the power capacity of wind power generators becomes large, wind power generator output can have an influence on the power system frequency. Therefore, this study investigates the influence of governor control systems of synchronous generators (SGs) for minimizing frequency fluctuations with high wind power penetration level, when a total capacity of SGs is considered as 100 MVA. It is seen that when both SGs operate as governor free (GF) operation, system perform better frequency control. But it can not be maintained to the acceptable level when SGs operate at GF-LFC or LFC-GF operation with wind power capacity about 5% of total capacity. Finally, it is seen that when several interconnected SGs are operated with different control modes, system frequency become more severe for 10% capacity of wind power. DOI: http://dx.doi.org/10.11591/ijece.v2i1.180
  • 其他摘要:As wind turbine output is proportional to the cube of wind speed, the wind turbine generator output fluctuates due to wind speed variations. Hence, if the power capacity of wind power generators becomes large, wind power generator output can have an influence on the power system frequency. Therefore, this study investigates the influence of governor control systems of synchronous generators (SGs) for minimizing frequency fluctuations with high wind power penetration level, when a total capacity of SGs is considered as 100 MVA. It is seen that when both SGs operate as governor free (GF) operation, system perform better frequency control. But it can not be maintained to the acceptable level when SGs operate at GF-LFC or LFC-GF operation with wind power capacity about 5% of total capacity. Finally, it is seen that when several interconnected SGs are operated with different control modes, system frequency become more severe for 10% capacity of wind power. DOI: http://dx.doi.org/10.11591/ijece.v2i1.180
Loading...
联系我们|关于我们|网站声明
国家哲学社会科学文献中心版权所有