期刊名称:IOP Conference Series: Earth and Environmental Science
印刷版ISSN:1755-1307
电子版ISSN:1755-1315
出版年度:2018
卷号:186
期号:5
页码:012028
DOI:10.1088/1755-1315/186/5/012028
语种:English
出版社:IOP Publishing
摘要:The micro increase output test is a reliable and effective way to obtain the back pressure correction curve of steam turbines. The test results are not only applicable to daily energy-saving analysis of steam turbines, but also instructive in the optimal operation of circulating water system. With a 660MW ultra-supercritical steam turbine unit as the research object, the back pressure correction curves of the unit THA condition, 75%THA condition and 50%THA condition were obtained by the micro increase output test. During the test, the flow of condensate was kept unchanged to avoid the influence of the changes of the low-pressure regenerative extraction flow on the test results.