首页    期刊浏览 2024年11月27日 星期三
登录注册

文章基本信息

  • 标题:Vessel density and En-face segmentation of optical coherence tomography angiography to analyse corneal vascularisation in an animal model
  • 作者:Kavya Devarajan ; Kavya Devarajan ; Wen Di Lee
  • 期刊名称:Eye and Vision
  • 印刷版ISSN:2326-0254
  • 出版年度:2019
  • 卷号:6
  • 期号:1
  • 页码:2
  • DOI:10.1186/s40662-018-0128-8
  • 语种:English
  • 出版社:BioMed Central
  • 摘要:Optical coherence tomography angiography (OCTA) is a novel non-invasive angiography technology that has recently been extensively studied for its utility in anterior segment imaging. In this study, we compared a split-spectrum amplitude decorrelation angiography (SSADA) OCTA and an optical micro-angiography (OMAG SD) OCTA system to current angiographic technique, indocyanine green angiography (ICGA), to assess corneal vascularisation in an animal model. We imaged 16 rabbits, (one eye per animal) with corneal vascularisation using SSADA OCTA (AngioVue; Optovue Inc., USA), OMAG OCTA (Angioscan; RS-3000 Nidek Co. Ltd., Japan) and ICGA in the same region of interest of the cornea at successive time-points. We then analysed all scanned images for vessel density measurements and used paired t-tests and Bland-Altman plots to examine for significant differences. The en-face segmentation images from each of the OCTA scans were also extracted and were matched at every 50 μm segmentation to be compared for vessel density at the respective depths. Bland-Altman plots revealed a good agreement between all three imaging techniques (P > 0.05) for all vessel density measurements computed, and the ranges of 95% limit of agreement were acceptable from a clinical perspective. No significant difference was reported, with ICGA (μ = 16.52 ± 8.94%) being more comparable to the OMAG OCTA (μ = 16.23 ± 9.51%; p = 0.50) than the SSADA OCTA (μ = 17.09 ± 7.34%; p = 0.33) system. Also, a good correlation value (r > 0.9) was obtained when comparing the vessel density measurements of the en-face segmentations between the OCTA systems. Comparable vessel density quantification between the two OCTA systems, and with ICGA was obtained. Segmentation analysis of the vasculature at different depths showed varied performance in the two OCTA systems relative to each other. The implications of the study may help to aid in the development of better OCTA algorithms for the anterior segment and its use in clinical translational research.
  • 关键词:OCTA ; Corneal vascularisation ; Optical micro angiography ; Split-spectrum amplitude decorrelation angiography ; Vessel density ; Anterior segment ; En-face OCTA
Loading...
联系我们|关于我们|网站声明
国家哲学社会科学文献中心版权所有