首页    期刊浏览 2024年07月08日 星期一
登录注册

文章基本信息

  • 标题:Automated Detection of Iris Furrows and their Influence on Dynamic Iris Volume Change
  • 本地全文:下载
  • 作者:Jacqueline Chua ; Sri Gowtham Thakku ; Tan Hung Pham
  • 期刊名称:Scientific Reports
  • 电子版ISSN:2045-2322
  • 出版年度:2017
  • 卷号:7
  • 期号:1
  • 页码:17894
  • DOI:10.1038/s41598-017-18039-w
  • 语种:English
  • 出版社:Springer Nature
  • 摘要:We introduced a new method for detecting iris surface furrows and identify its associations with dynamic changes in iris volume in healthy eyes. Swept-source optical coherence tomography was performed on 65 subjects with open angle under light and dark conditions. Iris boundaries were identified and a reconstruction of the anterior iris surface was obtained. Furrows were detected by identifying locally deep (minima) points on the iris surface and reported as furrow length in millimetres. Iris volume was quantified. Associations between furrow length and dynamic changes in iris volume were assessed using linear regression model. With pupil dilation, furrow length increased (15.84 mm) whereas iris volume decreased (-1.19 ± 0.66 mm3). Longer furrow length was associated with larger static iris volume, as well as smaller loss of iris volume with pupil dilation (β = -0.10, representing 0.1 mm3 less loss in iris volume per 10 mm increase in iris furrow length; P = 0.002, adjusted for age, gender and changes in pupil size). Our iris furrow length measurements are robust and intuitive. Eyes with longer furrows have larger iris volume and lose less volume during physiological pupil dilation. These findings highlight the potential for iris surface features as indicators of iris morphological behavior.
国家哲学社会科学文献中心版权所有