期刊名称:International Journal of Advanced Computer Science and Applications(IJACSA)
印刷版ISSN:2158-107X
电子版ISSN:2156-5570
出版年度:2019
卷号:10
期号:3
页码:383-389
DOI:10.14569/IJACSA.2019.0100350
出版社:Science and Information Society (SAI)
摘要:In this paper, we describe a simulation system of myopathicsurface electromyography (sEMG) signals. The architecture of the proposed system consists of two cascading modules. SEMG signals of three pathological skeletal muscles (Biceps Brachii, InterosseursDorsalis, TibalisAnterior) were generated. Root Mean Square (RMS Envelope) and Power Spectral Density (PSD) were used to validate our system.
关键词:Component; Surface Electromyography (sEMG); myopathy; root mean square; Power Spectral Density (PSD; skeletal muscles; biceps brachii; interosseous dorsalis; tibialis anterior