首页    期刊浏览 2024年11月27日 星期三
登录注册

文章基本信息

  • 标题:Monitor unit optimization in stereotactic body radiotherapy for small peripheral non-small cell lung cancer patients
  • 本地全文:下载
  • 作者:Bao-Tian Huang ; Zhu Lin ; Pei-Xian Lin
  • 期刊名称:Scientific Reports
  • 电子版ISSN:2045-2322
  • 出版年度:2016
  • 卷号:5
  • 期号:1
  • DOI:10.1038/srep18453
  • 语种:English
  • 出版社:Springer Nature
  • 摘要:The increasingly attractive stereotactic body radiotherapy (SBRT) treatment for stage I lung cancer is concomitant with a large amount of monitor units (MU), leading to excessive out-of-field dose and prolonged beam-on time. The study aims to reduce the MU number and shorten the beam-on time by optimizing the planning parameters. Clinically acceptable treatment plans from fourteen patients suffered from peripheral stage I non-small cell lung cancer (NSCLC) were created in the study. Priority for the upper objective of the target (PUOT), strength and Max MU setting in the MU objective function (MUOF) were adjusted respectively to investigate their effect on MU number, organs at risk (OARs) sparing and beam-on time. We found that the planning parameters influenced the MU number in a PUOT, strength and Max MU dependent manner. Combined with high priority for the UOT (HPUOT) and MUOF, the MU number was reduced from 443 ± 25 to 228 ± 22 MU/Gy without compromising the target coverage and OARs sparing. We also found beam-on time was proportional to MU number and it could be shortened from 7.9 ± 0.5 to 4.1 ± 0.4 minutes.
国家哲学社会科学文献中心版权所有