首页    期刊浏览 2024年11月24日 星期日
登录注册

文章基本信息

  • 标题:High-contrast grating resonators for label-free detection of disease biomarkers
  • 本地全文:下载
  • 作者:Tianbo Sun ; Shu Kan ; Gerard Marriott
  • 期刊名称:Scientific Reports
  • 电子版ISSN:2045-2322
  • 出版年度:2016
  • 卷号:6
  • 期号:1
  • DOI:10.1038/srep27482
  • 语种:English
  • 出版社:Springer Nature
  • 摘要:A label-free optical biosensor is described that employs a silicon-based high-contrast grating (HCG) resonator with a spectral linewidth of ~500 pm that is sensitive to ligand-induced changes in surface properties. The device is used to generate thermodynamic and kinetic data on surface-attached antibodies with their respective antigens. The device can detect serum cardiac troponin I, a biomarker of cardiac disease to 100 pg/ml within 4 mins, which is faster, and as sensitive as current enzyme-linked immuno-assays for cTnI.