首页    期刊浏览 2024年11月24日 星期日
登录注册

文章基本信息

  • 标题:Nondestructive detection of lead chrome green in tea by Raman spectroscopy
  • 本地全文:下载
  • 作者:Xiao-Li Li ; Chan-Jun Sun ; Liu-Bin Luo
  • 期刊名称:Scientific Reports
  • 电子版ISSN:2045-2322
  • 出版年度:2015
  • 卷号:5
  • 期号:1
  • DOI:10.1038/srep15729
  • 语种:English
  • 出版社:Springer Nature
  • 摘要:Raman spectroscopy was first adopted for rapid detecting a hazardous substance of lead chrome green in tea, which was illegally added to tea to disguise as high-quality. 160 samples of tea infusion with different concentrations of lead chrome green were prepared for Raman spectra acquirement in the range of 2804 cm−1–230 cm−1 and the spectral intensities were calibrated with relative intensity standards. Then wavelet transformation (WT) was adopted to extract information in different time and frequency domains from Raman spectra, and the low-frequency approximation signal (ca4) was proved as the most important information for establishment of lead chrome green measurement model, and the corresponding partial least squares (PLS) regression model obtained good performance in prediction with Rp and RMSEP of 0.936 and 0.803, respectively. To further explore the important wavenumbers closely related to lead chrome green, successive projections algorithm (SPA) was proposed. Finally, 8 characteristic wavenumbers closely related to lead chrome green were obtained and a more convenient and fast model was also developed. These results proved the feasibility of Raman spectroscopy for nondestructive detection of lead chrome green in tea quality control.
国家哲学社会科学文献中心版权所有