摘要:Fluorescence endomicroscopy provides quick access to molecular targets, while Raman spectroscopy allows the detection of multiple molecular targets. Using a simultaneous fluorescence-Raman endoscopic system (FRES), we herein demonstrate its potential in cancer diagnosis in an orthotopically induced colorectal cancer (CRC) xenograft model. In the model, epidermal growth factor receptor (EGFR) and vascular endothelial growth factor (VEGF) were targeted with antibody-conjugated fluorescence and surface-enhanced Raman scattering (F-SERS) dots. FRES demonstrated fast signal detection and multiplex targeting ability using fluorescence and Raman signals to detect the F-SERS dots. In addition, FRES showed a multiplex targeting ability even on a subcentimeter-sized CRC after spraying with a dose of 50 µg F-SERS dots. In conclusion, molecular characteristics of tumor cells (EGFR in cancer cell membranes) and tumor microenvironments (VEGF in the extracellular matrix) could be simultaneously investigated when performing a colonoscopy.