摘要:As a coherent diffractive imaging technique, axial multi-image phase retrieval utilizes a series of diffraction patterns on the basis of axial movement diversity to reconstruct full object wave field. Theoretically, fast convergence and high-accuracy of axial multi-image phase retrieval are demonstrated. In experiment, its retrieval suffers from the tilt illumination, in which diffraction patterns will shift in the lateral direction as the receiver traverses along the axis. In this case, the reconstructed result will be blurry or even mistaken. To solve this problem, we introduce cross-correlation calibration to derive the oblique angle and employ tilt diffraction into axial phase retrieval to recover a target, which is successfully demonstrated in simulation and experiment. Also, our method could provide a useful guidance for measuring how obliquely the incident light illuminates in an optical system.