首页    期刊浏览 2024年07月16日 星期二
登录注册

文章基本信息

  • 标题:Electro-echocardiographic Indices to Predict Cardiac Resynchronization Therapy Non-response on Non-ischemic Cardiomyopathy
  • 本地全文:下载
  • 作者:Ziqing Yu ; Xueying Chen ; Fei Han
  • 期刊名称:Scientific Reports
  • 电子版ISSN:2045-2322
  • 出版年度:2017
  • 卷号:7
  • 期号:1
  • DOI:10.1038/srep44009
  • 语种:English
  • 出版社:Springer Nature
  • 摘要:Cardiac resynchronization therapy (CRT) threw lights on heart failure treatment, however, parts of patients showed nonresponse to CRT. Unfortunately, it lacks effective parameters to predict CRT non-response. In present study, we try to seek effective electro-echocardiographic predictors on CRT non-response. This is a retrospective study to review a total of 227 patients of dyssynchronous heart failure underwent CRT implantation. Logistic analysis was performed between CRT responders and CRT non-responders. The primary outcome was the occurrence of improved left ventricular ejection fraction 1 year after CRT implantation. We concluded that LVEDV > 255 mL (OR = 2.236; 95% CI, 1.016-4.923) rather than LVESV > 160 mL (OR = 1.18; 95% CI, 0.544-2.56) and TpTe/QTc > 0.203 (OR = 5.206; 95% CI, 1.89-14.34) significantly predicted CRT non-response. Oppositely, S wave > 5.7 cm/s (OR = 0.242; 95% CI, 0.089-0.657), E/A > 1 (OR = 0.211; 95% CI, 0.079-0.566), E'/A' > 1 (OR = 0.054; 95% CI, 0.017-0.172), CLBBB (OR = 0.141; 95% CI, 0.048-0.409), and QRS duration >160 ms (OR = 0.52; 95% CI, 0.305-0.922) surprisingly predicted low-probability of CRT non-response.
国家哲学社会科学文献中心版权所有