摘要:In a power plant, the bellows of the lower part of the expansion joint for pumping and heating of the NO.8 turbo-generator unit breaked, and the internal guide plate was teared along the welding seam. Through observation of macroscopic morphology, hardness analysis, metallographic examination, energy spectrum analysis and other means, the corrugated pipe material itself unqualified performance, stress corrosion cracking, corrosion and other reasons were eliminated. According to the micro-characteristics of fatigue fracture and the service environment of the bellows, it is concluded that the main reason of break is the fatigue cracking of the bellows under the impact of the air flow and vibration.