期刊名称:IOP Conference Series: Earth and Environmental Science
印刷版ISSN:1755-1307
电子版ISSN:1755-1315
出版年度:2019
卷号:300
期号:4
页码:1-6
DOI:10.1088/1755-1315/300/4/042059
出版社:IOP Publishing
摘要:When a power plant ultra-supercritical 1000MW steam turbine generator set was started in a cold state, the vibration value of NO.3 bearing bush exceeded the alarm value. Based on the mechanism of vibration, the fault diagnosis and troubleshooting of excessive vibration of the NO.3 bearing bush were carried out by consulting the historical operation trend and checking the maintenance records, and the cause of the fault was accurately analyzed. By adopting effective measures such as setting up the heating system of the middle pressure cylinder and setting up the starting steam parameters reasonably, the problem of excessive vibration value of the NO.3 bearing bush was completely solved and the hidden danger of equipment operation safety was eliminated.