首页    期刊浏览 2024年07月05日 星期五
登录注册

文章基本信息

  • 标题:Evaluation of Short-Distance Airborne Infection Risk Using a Cough Generator
  • 本地全文:下载
  • 作者:Wei Ling ; Maho Ichikawa ; Kaho Hashimoto
  • 期刊名称:E3S Web of Conferences
  • 印刷版ISSN:2267-1242
  • 电子版ISSN:2267-1242
  • 出版年度:2019
  • 卷号:111
  • 页码:1-4
  • DOI:10.1051/e3sconf/201911102028
  • 出版社:EDP Sciences
  • 摘要:Short-distance airborne infections are often thought to occur by large droplets or direct contact. Recent studies have investigated the phenomenon of short-range airborne infection. In this study, the effect of relative humidity and short-distance exposure to cough droplet nuclei were evaluated. The evaluation model for infection risk was designed based on experimental data and previous studies and included sampling efficiency and virus survival rate. As observed in the comparison between short-range exposure and long-range exposure, the short-range exposure to the droplet nuclei by one cough was equivalent to a long-range exposure of several seconds to, depending on the number of ventilations, even for a momentary high-concentration exposure. This suggests the possibility of an infection risk corresponding to the receiving condition. Since short-range exposure and long-range exposure have different factors affecting the risk of infection, it is suggested that effective infection control should be selected for each condition. The risk of infection due to long-range exposure is considered to be sufficiently reduced to that of a single cough if the building meets the necessary number of ventilations. It was suggested that the influence of relative humidity on infection risks is smaller than other factors such as ventilation.
  • 其他摘要:Short-distance airborne infections are often thought to occur by large droplets or direct contact. Recent studies have investigated the phenomenon of short-range airborne infection. In this study, the effect of relative humidity and short-distance exposure to cough droplet nuclei were evaluated. The evaluation model for infection risk was designed based on experimental data and previous studies and included sampling efficiency and virus survival rate. As observed in the comparison between short-range exposure and long-range exposure, the short-range exposure to the droplet nuclei by one cough was equivalent to a long-range exposure of several seconds to, depending on the number of ventilations, even for a momentary high-concentration exposure. This suggests the possibility of an infection risk corresponding to the receiving condition. Since short-range exposure and long-range exposure have different factors affecting the risk of infection, it is suggested that effective infection control should be selected for each condition. The risk of infection due to long-range exposure is considered to be sufficiently reduced to that of a single cough if the building meets the necessary number of ventilations. It was suggested that the influence of relative humidity on infection risks is smaller than other factors such as ventilation.
国家哲学社会科学文献中心版权所有