首页    期刊浏览 2024年09月15日 星期日
登录注册

文章基本信息

  • 标题:Development of zero energy flexible unit with no Infrastructure for disaster and disaster response
  • 本地全文:下载
  • 作者:Beungyong Park ; Jinkyun Cho ; Yongdae Jeong
  • 期刊名称:E3S Web of Conferences
  • 印刷版ISSN:2267-1242
  • 电子版ISSN:2267-1242
  • 出版年度:2019
  • 卷号:111
  • 页码:1-6
  • DOI:10.1051/e3sconf/201911106003
  • 出版社:EDP Sciences
  • 摘要:In this paper a new kind of unit-prefabricated building is shown. The unit-prefabricated buildings are made up living unit, energy unit, water unit. The each unit was adapted new combine structure function as a high flexible design type. Moreover the design trend implemented the energy insulation, Solar PV panels, Energy storage system which are maintained for zero energy buildings. We made a prototype for zero energy flexible residential unit. The first step, we was evaluated physical performance and living environment, insulation, airtightness, thermal environmental, acoustic performance. The second step we was evaluated energy performance building to design heating and cooling system to combined PV, ESS system in the different plan type, and climate. As a results, The insulation performance wall was 0.18 W/(m2•K). The results of air-tightness was 12.13 ACH@50 (1/h). Further research we develop the structure and construction technology for zero energy flexible unit. To designed the high performance energy performance for zero energy building in the natural disaster.
  • 其他摘要:In this paper a new kind of unit-prefabricated building is shown. The unit-prefabricated buildings are made up living unit, energy unit, water unit. The each unit was adapted new combine structure function as a high flexible design type. Moreover the design trend implemented the energy insulation, Solar PV panels, Energy storage system which are maintained for zero energy buildings. We made a prototype for zero energy flexible residential unit. The first step, we was evaluated physical performance and living environment, insulation, airtightness, thermal environmental, acoustic performance. The second step we was evaluated energy performance building to design heating and cooling system to combined PV, ESS system in the different plan type, and climate. As a results, The insulation performance wall was 0.18 W/(m2•K). The results of air-tightness was 12.13 ACH@50 (1/h). Further research we develop the structure and construction technology for zero energy flexible unit. To designed the high performance energy performance for zero energy building in the natural disaster.
国家哲学社会科学文献中心版权所有