首页    期刊浏览 2024年10月07日 星期一
登录注册

文章基本信息

  • 标题:Study of Sensor Deflection in Hip Simulator : Numerical and Experimental Method
  • 本地全文:下载
  • 作者:Fabian Singgih Wicaksono ; T Towijaya ; Eko Saputra
  • 期刊名称:E3S Web of Conferences
  • 印刷版ISSN:2267-1242
  • 电子版ISSN:2267-1242
  • 出版年度:2018
  • 卷号:73
  • 页码:1-4
  • DOI:10.1051/e3sconf/20187301022
  • 出版社:EDP Sciences
  • 摘要:A lot of Hip Joint Simulator have been made nowadays, most of them use different structure and method. This research reports a pin-on-ring tribometer design that is used to became hip joint simulator based on the movement of the salat (salat gait). Modified femoral head and acetabular cup holder are performed, to design a reciprocating motion for simulation of artificial hip movement. An interesting finding from this study is a new linked-bar mechanism that leads to the ability to move femoral head against the acetabular cup and measure wear volume of an THR patients during normal salat gait. The designed motion angle is 121.5° in the flexion direction and 15.5° in the direction of abduction. Linked bar for sensor dial indicator have enough adjustment, but there is still a movement that is not rigid upon running hip joint process simulator. This research concentrates on the bar is already linked in accordance or not when compared with the data in the simulate on a computer. Estimation error and deviations that occur between numerical and experimental is going forward to improve hip joint simulator Undip to be more precise and relevant research to use THR Undip.
  • 其他摘要:A lot of Hip Joint Simulator have been made nowadays, most of them use different structure and method. This research reports a pin-on-ring tribometer design that is used to became hip joint simulator based on the movement of the salat (salat gait). Modified femoral head and acetabular cup holder are performed, to design a reciprocating motion for simulation of artificial hip movement. An interesting finding from this study is a new linked-bar mechanism that leads to the ability to move femoral head against the acetabular cup and measure wear volume of an THR patients during normal salat gait. The designed motion angle is 121.5° in the flexion direction and 15.5° in the direction of abduction. Linked bar for sensor dial indicator have enough adjustment, but there is still a movement that is not rigid upon running hip joint process simulator. This research concentrates on the bar is already linked in accordance or not when compared with the data in the simulate on a computer. Estimation error and deviations that occur between numerical and experimental is going forward to improve hip joint simulator Undip to be more precise and relevant research to use THR Undip.
  • 关键词:hip joint simulator; deflection; linked bar; cantilever; dial indicator
  • 其他关键词:hip joint simulator ; deflection ; linked bar ; cantilever ; dial indicator
国家哲学社会科学文献中心版权所有