期刊名称:IOP Conference Series: Earth and Environmental Science
印刷版ISSN:1755-1307
电子版ISSN:1755-1315
出版年度:2019
卷号:310
期号:3
页码:1-5
DOI:10.1088/1755-1315/310/3/032050
出版社:IOP Publishing
摘要:The on-site vibration test and diagnostic analysis of the condensate pump motor vibration of a 390 MW gas turbine unit in a power plant were carried out. It is considered that the serious imbalance of the rotor of the condensate pump motor is the main cause of the vibration abnormality of the motor. The vibration anomaly is eliminated by the on-site dynamic balance test.