摘要:Fine particulate matter (PM2.5) pose a serious threat to health. Therefore it should be monitored to assess its health impacts and to take actions to reduce its pollution. However, the traditional regulatory measuring stations are not able to capture the spatial and temporal variability of PM2.5 concentrations. The opportunity to improve the resolution of PM2.5 data is based on dense networks of miniaturized low-cost sensors. The article presents the sensor network for campus area of Wrocław University of Science and Technology. This system consists of 20 sensor nodes, distributed both on a narrow scale (14 devices on the main campus area) and on a wide scale (devices on campuses in distant parts of the city). Sensor devices have been equipped with optical sensors A003 from Plantower company and with heated inlets. Dedicated website with a map is used to present the up-to-date information about air quality to the public. Messages on air quality are based on air quality index, calculated every 15 minutes. The article demonstrates also few results of preliminary measurements, when episodes of elevated PM2.5 concentrations were observed. Sensor nodes proved to be an useful tool to monitor the changes of air pollution during such events.
其他摘要:Fine particulate matter (PM2.5) pose a serious threat to health. Therefore it should be monitored to assess its health impacts and to take actions to reduce its pollution. However, the traditional regulatory measuring stations are not able to capture the spatial and temporal variability of PM2.5 concentrations. The opportunity to improve the resolution of PM2.5 data is based on dense networks of miniaturized low-cost sensors. The article presents the sensor network for campus area of Wrocław University of Science and Technology. This system consists of 20 sensor nodes, distributed both on a narrow scale (14 devices on the main campus area) and on a wide scale (devices on campuses in distant parts of the city). Sensor devices have been equipped with optical sensors A003 from Plantower company and with heated inlets. Dedicated website with a map is used to present the up-to-date information about air quality to the public. Messages on air quality are based on air quality index, calculated every 15 minutes. The article demonstrates also few results of preliminary measurements, when episodes of elevated PM2.5 concentrations were observed. Sensor nodes proved to be an useful tool to monitor the changes of air pollution during such events.