首页    期刊浏览 2024年11月25日 星期一
登录注册

文章基本信息

  • 标题:Differentiation Image Quality of MRI Shoulder Joint with Variation RF Coils
  • 本地全文:下载
  • 作者:Sri Mulyati ; Luthfi Rusyadi ; Ika Mentari Putri Rahmawati
  • 期刊名称:E3S Web of Conferences
  • 印刷版ISSN:2267-1242
  • 电子版ISSN:2267-1242
  • 出版年度:2019
  • 卷号:125
  • 页码:1-5
  • DOI:10.1051/e3sconf/201912518001
  • 出版社:EDP Sciences
  • 摘要:Image Quality of Magnetic Resonance Imaging (MRI) has several factors including SNR dan CNR. Influence Factors of SNR depends on the coil used. MRI shoulder joints in several hospitals can be done with different RF Coil, there are M coil flex and shoulder coil. Are there differences in image quality with MRI shoulder joints between the two coils. This study was conducted to determine differentiation SNR and CNR between them in the coronal proton density sequence of MR shoulder joint. This research was quantitative research with an experimental approach. Scanning was done by using Flex M Coil and shoulder coil with 10 samples. The quality image evaluated of SNR and CNR, data were analyzed using paired t-test with α = 5%. The results of the research showed significant differentiation of image quality between using Flex M Coil and shoulder coil in coronal proton density-weighted of MRI Shoulder Joint with p-value SNR < 0,001 and CNR = 0,002. The average of SNR and CNR using shoulder coil is higher than using flex M coil, so the shoulder coil has the better image quality of coronal proton density-weighted MRI shoulder joint.
  • 其他摘要:Image Quality of Magnetic Resonance Imaging (MRI) has several factors including SNR dan CNR. Influence Factors of SNR depends on the coil used. MRI shoulder joints in several hospitals can be done with different RF Coil, there are M coil flex and shoulder coil. Are there differences in image quality with MRI shoulder joints between the two coils. This study was conducted to determine differentiation SNR and CNR between them in the coronal proton density sequence of MR shoulder joint. This research was quantitative research with an experimental approach. Scanning was done by using Flex M Coil and shoulder coil with 10 samples. The quality image evaluated of SNR and CNR, data were analyzed using paired t-test with α = 5%. The results of the research showed significant differentiation of image quality between using Flex M Coil and shoulder coil in coronal proton density-weighted of MRI Shoulder Joint with p-value SNR < 0,001 and CNR = 0,002. The average of SNR and CNR using shoulder coil is higher than using flex M coil, so the shoulder coil has the better image quality of coronal proton density-weighted MRI shoulder joint.
  • 其他关键词:Image Quality ; MRI Shoulder Joint ; Flex M Coil ; Shoulder Coil
国家哲学社会科学文献中心版权所有