首页    期刊浏览 2025年02月21日 星期五
登录注册

文章基本信息

  • 标题:Optimization of capillary tube dimensions using different Refrigerants for 1.5 ton mobile air conditioner
  • 本地全文:下载
  • 作者:Kasuba Sainath ; T. Kishen Kumar Reddy ; Suresh Akella
  • 期刊名称:Case Studies in Thermal Engineering
  • 印刷版ISSN:2214-157X
  • 电子版ISSN:2214-157X
  • 出版年度:2019
  • 卷号:16
  • 页码:1-8
  • DOI:10.1016/j.csite.2019.100528
  • 出版社:Elsevier B.V.
  • 摘要:Capillary tube is one of the commonly used throttling devices in the refrigeration and the air conditioning systems. The capillary tube is made up of copper tube of very small internal diameter. It is of very long length and it is coiled to several turns so that it occupies less space. The internal diameter of the capillary tube used for the refrigeration and AC applications varies from 0.5 to 2.28 mm (0.020–0.09 inches). Capillary tube used as the throttling device in the refrigerators, deep freezers, water coolers and air conditioners. The objective of this research was to evaluate the optimum size of a capillary tube dimensions in a Air Conditioning system and to determine the Pressure drop across the capillary tube. The optimization was determined by mathematical calculation to evaluate increment length.
  • 关键词:ODP;GWP ; COP;Enthalpies ; cooling test ; Power consumption test ; Effect on climatic conditions ; CFM
国家哲学社会科学文献中心版权所有