  • 标题:Estudio comparativo entre la espectrofotometría de absorción atómica de llama y el método colorimétrico en el estado del zinc sérico
  • 本地全文:下载
  • 作者:Escobedo Monge, Marlene, Barrado, Enrique ; Alonso Vicente, Carmen ; Marugán de Miguelsanz, José Manuel
  • 期刊名称:Nutrición Clínica y Dietética Hospitalaria
  • 印刷版ISSN:0211-6057
  • 电子版ISSN:1989-208X
  • 出版年度:2018
  • 卷号:38
  • 期号:2
  • 页码:1-6
  • DOI:10.12873/382escobedo
  • 出版社:Sociedad Española de Dietética y Ciencias de la Alimentación (SEDCA)
  • 摘要:Introduction: Zinc is an essential trace element for human life and its deficiency affects human growth and development. Serum zinc concentration (SZnC) provides useful information in the clinical categorization of deficiency and toxicity states. Objectives: This paper presents a comparison study of Flame Atomic Absorption Spectrometry (FASS) and the Colorimetric method in the analysis of SZnC and hypozincemia. Methods: The serum concentrations of zinc of 93 patients (1 to 31 years old) with chronic diseases were used for analysis. Statistical analytical: for SZnC, Pearson correlation coefficient, simple linear regression analysis, Bland & Altman method (B&A), and concordance correlation coefficient (CCC) were valued; and for hypozincemia, the differences were studied and Cohen’s Kappa index was used. Results: The main results indicate the means of the SZnC by both methods presented neither significant difference (p=0.328) nor linear relation (R=0.18, p=0.077). Furthermore, the percentage of cases of hypozincemia by the Colorimetric method was almost double (13%) than by the FASS (8%). There was only one coincident case in both methods at <70 µg/dl. Discussion: The Colorimetric method in hypozincemia ranges predicted lower values with the FASS. This concordance poor between both methods was corroborated with a concordance correlation coefficient (CCC) lowly of 0.17. Moreover, the Cohen’s Kappa index (-0.013) shown a concordance poor between both methods, too. In other studies, the variability of SZnC by Colorimetric method is more than FASS. Conclusion: In summary, despite that, the mean of serum concentrations of zinc by both methods is similar; the diagnosis of cass with hypozincemia is not. The degree of agreement between methods is poor, with a poor strength of concordance to diagnosis hypozincemia. Therefore, we recommended the use of FASS to evaluated zinc status and diagnosis of hypozincemia, instead of the Colorimetric method.
  • 关键词:Serum zinc concentration; hypozincemia; Colorimetric method; flame atomic absorption spectrophotometry;
国家哲学社会科学文献中心版权所有