摘要:The physical demands of fast-medium bowling are increasingly being recognised, yet comparative exploration of the differing demands between competitive formats (i.e. one-day [OD] versus multi-day [MD] matches) remain minimal. The aim of this study was to describe in-match physiological profiles of professional fast-medium bowlers from England across different versions of competitive matches using a multivariable wearable monitoring device. Seven professional cricket fast-medium bowlers wore the BioharnessTM monitoring device during matches, over three seasons (>80 hours in-match). Heart Rate (HR) and Acceleromety (ACC) was compared across match types (OD, MD) and different in-match activity states (Bowling, Between over bowling, Fielding). Peak acceleration during OD bowling was significantly higher in comparison to MD cricket ([OD vs. MD] 234.1 ± 57.9 vs 226.6 ± 32.9 ct·episode-1, p < 0.05, ES = 0.11-0.30). Data for ACC were also higher during OD than MD fielding activities (p < 0.01, ES = 0.11-.30). OD bowling stimulated higher mean HR responses (143 ± 14 vs 137 ± 16 beats·min-1, p < 0.05, ES = 0.21) when compared to MD matches. This increase in OD cricket was evident for both between over (129 ± 9 vs 120 ± 13 beats·min-1,p < 0.01, ES = 0.11-0.50) and during fielding (115 ± 12 vs 106 ± 12 beats·min-1, p < 0.01, ES = 0.36) activity. The increased HR and ACC evident in OD matches suggest greater acute physical loads than MD formats. Therefore, use of wearable technology and the findings provided give a valuable appreciation of the differences in match loads, and thus required physiological preparation and recovery in fast-medium bowlers.