期刊名称:Analele Universităţii din Oradea: Seria Geografie
印刷版ISSN:1221-1273
电子版ISSN:2065-3409
出版年度:2013
卷号:23
期号:1
页码:181-189
语种:English
出版社:University of Oradea Publishing House
摘要:Air pollution from cement factory is classified as one of the sources of air pollution. The control of the air pollution by addressing the wind field dynamics was the main objective of the paper. The dynamics of dispersion showed a three way flow which was calculated and explained accordingly. The 3D model showed good level of accuracy by determining field values of air deposited pollutants. Mean concentration of diffusing pollutants was shown to be directly proportional to the plume angular displacement. The 2D model explained the details of the wind field dynamics and proffers a solution which may be relevant in controlling air pollution from anthropogenic sources.
关键词:contaminant; advection; drag force; semi-plume model