首页    期刊浏览 2024年09月16日 星期一
登录注册

文章基本信息

  • 标题:Comparison of rating of perceived exertion scales during incremental and interval exercise
  • 本地全文:下载
  • 作者:Cristina Cortis ; Blaine E. Arney ; Carl Foster
  • 期刊名称:Kinesiology
  • 印刷版ISSN:1331-1441
  • 出版年度:2019
  • 卷号:51
  • 期号:2
  • 页码:150-157
  • DOI:10.26582/k.51.2.1
  • 出版社:Faculty of Kinesiology
  • 摘要:The Rating of Perceived Exertion (RPE) is an important measure of exercise intensity, which is useful both as a primary and adjunctive method of exercise prescription. However, there are multiple variants of the Borg RPE scale, primarily the Borg 6-20 RPE scale (BORG-RPE) and the Borg Category-Ratio-10 scale (BORG-CR10). There are inadequate data available to address the comparability and interchangeability of these two widely used scales. Well-trained non-athletes performed two increment cycle tests, with each scale used in a random sequence. Subjects also performed interval sessions at three intensities (50, 75 and 85% of peak power output) with each scale used in a random sequence. There were very large correlations during the incremental exercise between the conventional physiological measures (% heart rate reserve – r=0.89 & r=.87); and %VO2reserve (r=.88 & r=.90) and RPE measured by either the BORG-RPE or the BORGCR10, respectively. This pattern was also evident during the interval exercise (% heart rate reserve (r=.85 & r=.84; and blood lactate concentration – r=.74 & r=.78) and RPE measured by either the BORG-RPE or the BORG-CR10, respectively. The relationship between RPE measured by the BORG-RPE and the BORGCR10 was large and best described by a non-linear relationship for both the incremental (R2=89) and the interval (R2=.89) exercise. The incremental and interval curves were virtually overlapping. We concluded that the two most popular versions of the RPE scale, BORG-RPE and BORG-CR10, were both highly related to the conventional physiological measures and very strongly related to each other, with an easily described conversion.
  • 其他摘要:

    The Rating of Perceived Exertion (RPE) is an important measure of exercise intensity, which is useful both as a primary and adjunctive method of exercise prescription. However, there are multiple variants of the Borg RPE scale, primarily the Borg 6-20 RPE scale (BORG-RPE) and the Borg Category-Ratio-10 scale (BORG-CR10). There are inadequate data available to address the comparability and interchangeability of these two widely used scales. Well-trained non-athletes performed two increment cycle tests, with each scale used in a random sequence. Subjects also performed interval sessions at three intensities (50, 75 and 85% of peak power output) with each scale used in a random sequence. There were very large correlations during the incremental exercise between the conventional physiological measures (% heart rate reserve – r=0.89 & r=.87); and %VO2reserve (r=.88 & r=.90) and RPE measured by either the BORG-RPE or the BORGCR10, respectively. This pattern was also evident during the interval exercise (% heart rate reserve (r=.85 & r=.84; and blood lactate concentration – r=.74 & r=.78) and RPE measured by either the BORG-RPE or the BORG-CR10, respectively. The relationship between RPE measured by the BORG-RPE and the BORGCR10 was large and best described by a non-linear relationship for both the incremental (R2=89) and the interval (R2=.89) exercise. The incremental and interval curves were virtually overlapping. We concluded that the two most popular versions of the RPE scale, BORG-RPE and BORG-CR10, were both highly related to the conventional physiological measures and very strongly related to each other, with an easily described conversion.

  • 关键词:exercise prescription; perceived exertion; heart rate; oxygen uptake; lactate
国家哲学社会科学文献中心版权所有