摘要:In this paper, the influence of steel rate and substitution rate of iron tailing powder on the bearing capacity of the stub columns is mainly investigated through the test of five concrete stub columns under axial compression loading with square steel tube self-compacting iron tailing, and the test bearing capacity is compared with the bearing capacity calculated by each code. The test results show that the bearing capacity of the test piece increases obviously with the increase of the steel content; the bearing capacity of the test piece is less affected by the substitution rate of iron tailing powder; it is suggested to use code GB50936-2014 to design and calculate the bearing capacity of the stub column under axial compression loading.