首页    期刊浏览 2024年10月06日 星期日
登录注册

文章基本信息

  • 标题:Determination of two acrylates in environmental water by high performance liquid chromatography
  • 本地全文:下载
  • 作者:Yue Qiu ; Qing Zhang ; Genrong Li
  • 期刊名称:E3S Web of Conferences
  • 印刷版ISSN:2267-1242
  • 电子版ISSN:2267-1242
  • 出版年度:2021
  • 卷号:233
  • 页码:1023
  • DOI:10.1051/e3sconf/202123301023
  • 出版社:EDP Sciences
  • 摘要:A high performance liquid chromatography (HPLC) method was established for the determination of two acrylate substances in environmental water. The optimal chromatographic conditions were determined via exploring the effects of chromatographic column, mobile phase, column temperature, flow rate, detection wavelength and other factors on the separation effect of acrylate substances. Finally, the effective separation of methyl methacrylate and isopropyl methacrylate was realized within 6 min. The retention time of the target compound was used for qualitative analysis and the external standard method was used for quantitative analysis in the experiment. The linear relationship between the two acrylates was good in the range of 0.2-50.0 mg/L, and the correlation coefficient of standard curve was higher than 0.999. The recovery rate was 88.6%-105.3%, the relative standard deviation was 1.7%-4.1%, and the detection limit (LODs) was 0.03-0.05 mg/L. The method was simple, efficient and accurate, and suitable for the determination of acrylates in environmental water samples.
  • 其他摘要:A high performance liquid chromatography (HPLC) method was established for the determination of two acrylate substances in environmental water. The optimal chromatographic conditions were determined via exploring the effects of chromatographic column, mobile phase, column temperature, flow rate, detection wavelength and other factors on the separation effect of acrylate substances. Finally, the effective separation of methyl methacrylate and isopropyl methacrylate was realized within 6 min. The retention time of the target compound was used for qualitative analysis and the external standard method was used for quantitative analysis in the experiment. The linear relationship between the two acrylates was good in the range of 0.2-50.0 mg/L, and the correlation coefficient of standard curve was higher than 0.999. The recovery rate was 88.6%-105.3%, the relative standard deviation was 1.7%-4.1%, and the detection limit (LODs) was 0.03-0.05 mg/L. The method was simple, efficient and accurate, and suitable for the determination of acrylates in environmental water samples.
国家哲学社会科学文献中心版权所有