首页    期刊浏览 2024年11月28日 星期四
登录注册

文章基本信息

  • 标题:Estimated internal exposure doses due to indoor radiocaesium contamination in residential houses after the Fukushima nuclear accident
  • 本地全文:下载
  • 作者:Hiroko Yoshida-Ohuchi ; Naohide Shinohara
  • 期刊名称:Scientific Reports
  • 电子版ISSN:2045-2322
  • 出版年度:2020
  • 卷号:10
  • 期号:1
  • 页码:1-12
  • DOI:10.1038/s41598-020-74182-x
  • 出版社:Springer Nature
  • 摘要:This work first reports the estimation of the internal exposure from ingestion of house dust and inhalation of aerosol, by employing a measured data on 137Cs activities, bioaccessibility (solubility to water and 1 M HCl), and particle size distribution. The house dust and aerosol samples were collected during the actual indoor cleaning by vacuuming and dusting, from 65 houses and buildings in proximity to the Fukushima Daiichi nuclear power plant (FDNPP) (1.6–16.1 km from the FDNPP) during a period from April 2016 to January 2019. Committed effective doses for an adult owing to the ingestion of house dust of 20 mg per day, which adheres to one’s hands through the hand-to-mouth, and those owing to inhalation of aerosol during dusting for 1.5 h while wearing a mask, were calculated using DCAL software for each house or building, as 1.13 µSv and 4.55 µSv as maximum doses, respectively (as of March 2011). Both the committed effective doses, owing to ingestion and inhalation, were inversely correlated with the distance from the FDNPP, and positively correlated with the indoor surface contamination.
  • 其他摘要:Abstract This work first reports the estimation of the internal exposure from ingestion of house dust and inhalation of aerosol, by employing a measured data on 137 Cs activities, bioaccessibility (solubility to water and 1 M HCl), and particle size distribution. The house dust and aerosol samples were collected during the actual indoor cleaning by vacuuming and dusting, from 65 houses and buildings in proximity to the Fukushima Daiichi nuclear power plant (FDNPP) (1.6–16.1 km from the FDNPP) during a period from April 2016 to January 2019. Committed effective doses for an adult owing to the ingestion of house dust of 20 mg per day, which adheres to one’s hands through the hand-to-mouth, and those owing to inhalation of aerosol during dusting for 1.5 h while wearing a mask, were calculated using DCAL software for each house or building, as 1.13 µSv and 4.55 µSv as maximum doses, respectively (as of March 2011). Both the committed effective doses, owing to ingestion and inhalation, were inversely correlated with the distance from the FDNPP, and positively correlated with the indoor surface contamination.
国家哲学社会科学文献中心版权所有