首页    期刊浏览 2024年09月18日 星期三
登录注册

文章基本信息

  • 标题:Towards shifted position-diffuse reflectance imaging of anatomically correctly scaled human microvasculature
  • 本地全文:下载
  • 作者:Moritz Späth ; Martin Hohmann ; Clemens Roider
  • 期刊名称:Scientific Reports
  • 电子版ISSN:2045-2322
  • 出版年度:2020
  • 卷号:10
  • 期号:1
  • 页码:1-10
  • DOI:10.1038/s41598-020-74447-5
  • 出版社:Springer Nature
  • 摘要:Due to significant advantages, the trend in the field of medical technology is moving towards minimally or even non-invasive examination methods. In this respect, optical methods offer inherent benefits, as does diffuse reflectance imaging (DRI). The present study attempts to prove the suitability of DRI—when implemented alongside a suitable setup and data evaluation algorithm—to derive information from anatomically correctly scaled human capillaries (diameter: $$10\,\upmu \hbox {m}$$ , length: $$45\,\upmu \hbox {m}$$ ) by conducting extensive Monte–Carlo simulations and by verifying the findings through laboratory experiments. As a result, the method of shifted position-diffuse reflectance imaging (SP-DRI) is established by which average signal modulations of up to 5% could be generated with an illumination wavelength of $$\lambda =424\,\hbox {nm}$$ and a core diameter of the illumination fiber of $$50\,\upmu \hbox {m}$$ . No reference image is needed for this technique. The present study reveals that the diffuse reflectance data in combination with the SP-DRI normalization are suitable to localize human capillaries within turbid media.
  • 其他摘要:Abstract Due to significant advantages, the trend in the field of medical technology is moving towards minimally or even non-invasive examination methods. In this respect, optical methods offer inherent benefits, as does diffuse reflectance imaging (DRI). The present study attempts to prove the suitability of DRI—when implemented alongside a suitable setup and data evaluation algorithm—to derive information from anatomically correctly scaled human capillaries (diameter: $$10\,\upmu \hbox {m}$$ 10 μ m , length: $$45\,\upmu \hbox {m}$$ 45 μ m ) by conducting extensive Monte–Carlo simulations and by verifying the findings through laboratory experiments. As a result, the method of shifted position-diffuse reflectance imaging (SP-DRI) is established by which average signal modulations of up to 5% could be generated with an illumination wavelength of $$\lambda =424\,\hbox {nm}$$ λ = 424 nm and a core diameter of the illumination fiber of $$50\,\upmu \hbox {m}$$ 50 μ m . No reference image is needed for this technique. The present study reveals that the diffuse reflectance data in combination with the SP-DRI normalization are suitable to localize human capillaries within turbid media.
国家哲学社会科学文献中心版权所有