首页    期刊浏览 2024年07月08日 星期一
登录注册

文章基本信息

  • 标题:Custom extraction of macular ganglion cell-inner plexiform layer thickness more precisely co-localizes structural measurements with visual fields test grids
  • 本地全文:下载
  • 作者:Janelle Tong ; David Alonso-Caneiro ; Nayuta Yoshioka
  • 期刊名称:Scientific Reports
  • 电子版ISSN:2045-2322
  • 出版年度:2020
  • 卷号:10
  • 期号:1
  • 页码:1-13
  • DOI:10.1038/s41598-020-75599-0
  • 出版社:Springer Nature
  • 摘要:We aimed to evaluate methods of extracting optical coherence tomography (OCT)-derived macular ganglion cell-inner plexiform layer (GCIPL) thickness measurements over retinal locations corresponding to standard visual field (VF) test grids. A custom algorithm was developed to automatically extract GCIPL thickness measurements from locations corresponding to Humphrey Field Analyser 10-2 and 30-2 test grids over Goldmann II, III and V stimulus sizes from a healthy cohort of 478 participants. Differences between GCIPL thickness measurements based on VF test grids (VF-based paradigms) and the 8 × 8 grid, as per instrument review software, were analyzed, as were impacts of fovea to optic disc tilt and areas over which GCIPL thickness measurements were extracted. Significant differences between the VF-based paradigms and the 8 × 8 grid were observed at up to 55% of locations across the macula, with the greatest deviations at the fovea (median 25.5 μm, 95% CI 25.24–25.72 μm, P < .0001). While significant correlations with fovea to optic disc tilt were noted at up to 33% of locations distributed 6°–8° from the foveal center, there were no marked differences in GCIPL thickness measurements between VF-based paradigms using different stimulus sizes. As such, standard high-density OCT measurement paradigms do not adequately reflect GCIPL measurements at retinal locations tested with standard VF patterns, with the central macular region contributing most to the observed differences and with further correction required for fovea to optic disc tilt. Spatial direction of GCIPL thickness measurements will improve future comparisons of structure and function, thereby improving methods designed to detect pathology affecting the inner retina.
  • 其他摘要:Abstract We aimed to evaluate methods of extracting optical coherence tomography (OCT)-derived macular ganglion cell-inner plexiform layer (GCIPL) thickness measurements over retinal locations corresponding to standard visual field (VF) test grids. A custom algorithm was developed to automatically extract GCIPL thickness measurements from locations corresponding to Humphrey Field Analyser 10-2 and 30-2 test grids over Goldmann II, III and V stimulus sizes from a healthy cohort of 478 participants. Differences between GCIPL thickness measurements based on VF test grids (VF-based paradigms) and the 8 × 8 grid, as per instrument review software, were analyzed, as were impacts of fovea to optic disc tilt and areas over which GCIPL thickness measurements were extracted. Significant differences between the VF-based paradigms and the 8 × 8 grid were observed at up to 55% of locations across the macula, with the greatest deviations at the fovea (median 25.5 μm, 95% CI 25.24–25.72 μm, P  < .0001). While significant correlations with fovea to optic disc tilt were noted at up to 33% of locations distributed 6°–8° from the foveal center, there were no marked differences in GCIPL thickness measurements between VF-based paradigms using different stimulus sizes. As such, standard high-density OCT measurement paradigms do not adequately reflect GCIPL measurements at retinal locations tested with standard VF patterns, with the central macular region contributing most to the observed differences and with further correction required for fovea to optic disc tilt. Spatial direction of GCIPL thickness measurements will improve future comparisons of structure and function, thereby improving methods designed to detect pathology affecting the inner retina.
国家哲学社会科学文献中心版权所有