首页    期刊浏览 2025年02月20日 星期四
登录注册

文章基本信息

  • 标题:Tellurium doped zinc imidazole framework (Te@ZIF-8) for quantitative determination of hydrogen peroxide from serum of pancreatic cancer patients
  • 本地全文:下载
  • 作者:Batool Fatima ; Dilshad Hussain ; Adeela Saeed
  • 期刊名称:Scientific Reports
  • 电子版ISSN:2045-2322
  • 出版年度:2020
  • 卷号:10
  • 期号:1
  • 页码:1-9
  • DOI:10.1038/s41598-020-78115-6
  • 出版社:Springer Nature
  • 摘要:The tellurium doped zinc imidazole framework (Te@ZIF-8) is prepared by a two-step hydrothermal strategy for the electrochemical sensing of hydrogen peroxide. Material is characterized by transmission electron microscopy (TEM), energy-dispersive X-ray spectroscopy (EDS), X-ray diffraction (XRD), thermogravimetric analysis (TGA), and differential scanning calorimetry (DSC). The electrochemical characterization of the MOF modified electrode is done by a three-electrode system. Electrochemical sensing of hydrogen peroxide is made by cyclic voltammetry, amperometry, and impedance measurements. Results demonstrate that Te@ZIF-8 shows a detection limit of 60 µM with linearity up to 0.98855. Material is stable to 1000 cycles with no significant change in electrochemical response. Amperometry depicts the recovery of hydrogen peroxide from human serum up to 101%. Impedance curve reveals the surface of Te@ZIF-8-GCE (glassy carbon electrode) as porous and rough and an interface is developed between analyte ions and the sensing material. Finally, the modified electrode is used for the quantitative determination of hydrogen peroxide from serum samples of pancreatic cancer patients, diagnosed with CA 19-9.
  • 其他摘要:Abstract The tellurium doped zinc imidazole framework (Te@ZIF-8) is prepared by a two-step hydrothermal strategy for the electrochemical sensing of hydrogen peroxide. Material is characterized by transmission electron microscopy (TEM), energy-dispersive X-ray spectroscopy (EDS), X-ray diffraction (XRD), thermogravimetric analysis (TGA), and differential scanning calorimetry (DSC). The electrochemical characterization of the MOF modified electrode is done by a three-electrode system. Electrochemical sensing of hydrogen peroxide is made by cyclic voltammetry, amperometry, and impedance measurements. Results demonstrate that Te@ZIF-8 shows a detection limit of 60 µM with linearity up to 0.98855. Material is stable to 1000 cycles with no significant change in electrochemical response. Amperometry depicts the recovery of hydrogen peroxide from human serum up to 101%. Impedance curve reveals the surface of Te@ZIF-8-GCE (glassy carbon electrode) as porous and rough and an interface is developed between analyte ions and the sensing material. Finally, the modified electrode is used for the quantitative determination of hydrogen peroxide from serum samples of pancreatic cancer patients, diagnosed with CA 19-9.
国家哲学社会科学文献中心版权所有