首页    期刊浏览 2025年05月23日 星期五
登录注册

文章基本信息

  • 标题:Deep-learned time-signal intensity pattern analysis using an autoencoder captures magnetic resonance perfusion heterogeneity for brain tumor differentiation
  • 本地全文:下载
  • 作者:Ji Eun Park ; Ho Sung Kim ; Junkyu Lee
  • 期刊名称:Scientific Reports
  • 电子版ISSN:2045-2322
  • 出版年度:2020
  • 卷号:10
  • 期号:1
  • 页码:1-11
  • DOI:10.1038/s41598-020-78485-x
  • 出版社:Springer Nature
  • 摘要:Current image processing methods for dynamic susceptibility contrast (DSC) magnetic resonance imaging (MRI) do not capture complex dynamic information of time-signal intensity curves. We investigated whether an autoencoder-based pattern analysis of DSC MRI captured representative temporal features that improves tissue characterization and tumor diagnosis in a multicenter setting. The autoencoder was applied to the time-signal intensity curves to obtain representative temporal patterns, which were subsequently learned by a convolutional neural network. This network was trained with 216 preoperative DSC MRI acquisitions and validated using external data (n = 43) collected with different DSC acquisition protocols. The autoencoder applied to time-signal intensity curves and clustering obtained nine representative clusters of temporal patterns, which accurately identified tumor and non-tumoral tissues. The dominant clusters of temporal patterns distinguished primary central nervous system lymphoma (PCNSL) from glioblastoma (AUC 0.89) and metastasis from glioblastoma (AUC 0.95). The autoencoder captured DSC time-signal intensity patterns that improved identification of tumoral tissues and differentiation of tumor type and was generalizable across centers.
  • 其他摘要:Abstract Current image processing methods for dynamic susceptibility contrast (DSC) magnetic resonance imaging (MRI) do not capture complex dynamic information of time-signal intensity curves. We investigated whether an autoencoder-based pattern analysis of DSC MRI captured representative temporal features that improves tissue characterization and tumor diagnosis in a multicenter setting. The autoencoder was applied to the time-signal intensity curves to obtain representative temporal patterns, which were subsequently learned by a convolutional neural network. This network was trained with 216 preoperative DSC MRI acquisitions and validated using external data (n = 43) collected with different DSC acquisition protocols. The autoencoder applied to time-signal intensity curves and clustering obtained nine representative clusters of temporal patterns, which accurately identified tumor and non-tumoral tissues. The dominant clusters of temporal patterns distinguished primary central nervous system lymphoma (PCNSL) from glioblastoma (AUC 0.89) and metastasis from glioblastoma (AUC 0.95). The autoencoder captured DSC time-signal intensity patterns that improved identification of tumoral tissues and differentiation of tumor type and was generalizable across centers.
国家哲学社会科学文献中心版权所有