首页    期刊浏览 2024年07月07日 星期日
登录注册

文章基本信息

  • 标题:Practicable assessment of cochlear size and shape from clinical CT images
  • 本地全文:下载
  • 作者:Andrew H. Gee ; Yufeng Zhao ; Graham M. Treece
  • 期刊名称:Scientific Reports
  • 电子版ISSN:2045-2322
  • 出版年度:2021
  • 卷号:11
  • 期号:1
  • 页码:3448
  • DOI:10.1038/s41598-021-83059-6
  • 出版社:Springer Nature
  • 摘要:There is considerable interpersonal variation in the size and shape of the human cochlea, with evident consequences for cochlear implantation. The ability to characterize a specific cochlea, from preoperative computed tomography (CT) images, would allow the clinician to personalize the choice of electrode, surgical approach and postoperative programming. In this study, we present a fast, practicable and freely available method for estimating cochlear size and shape from clinical CT. The approach taken is to fit a template surface to the CT data, using either a statistical shape model or a locally affine deformation (LAD). After fitting, we measure cochlear size, duct length and a novel measure of basal turn non-planarity, which we suggest might correlate with the risk of insertion trauma. Gold-standard measurements from a convenience sample of 18 micro-CT scans are compared with the same quantities estimated from low-resolution, noisy, pseudo-clinical data synthesized from the same micro-CT scans. The best results were obtained using the LAD method, with an expected error of 8-17% of the gold-standard sample range for non-planarity, cochlear size and duct length.
  • 其他摘要:Abstract There is considerable interpersonal variation in the size and shape of the human cochlea, with evident consequences for cochlear implantation. The ability to characterize a specific cochlea, from preoperative computed tomography (CT) images, would allow the clinician to personalize the choice of electrode, surgical approach and postoperative programming. In this study, we present a fast, practicable and freely available method for estimating cochlear size and shape from clinical CT. The approach taken is to fit a template surface to the CT data, using either a statistical shape model or a locally affine deformation (LAD). After fitting, we measure cochlear size, duct length and a novel measure of basal turn non-planarity, which we suggest might correlate with the risk of insertion trauma. Gold-standard measurements from a convenience sample of 18 micro-CT scans are compared with the same quantities estimated from low-resolution, noisy, pseudo-clinical data synthesized from the same micro-CT scans. The best results were obtained using the LAD method, with an expected error of 8–17% of the gold-standard sample range for non-planarity, cochlear size and duct length.
国家哲学社会科学文献中心版权所有