首页    期刊浏览 2024年11月30日 星期六
登录注册

文章基本信息

  • 标题:Effects of 2% sodium fluoride solution on the prevention of streptococcal adhesion to titanium and zirconia surfaces
  • 本地全文:下载
  • 作者:Yukari Oda ; Tadashi Miura ; Tomoki Hirano
  • 期刊名称:Scientific Reports
  • 电子版ISSN:2045-2322
  • 出版年度:2021
  • 卷号:11
  • 期号:1
  • 页码:4498
  • DOI:10.1038/s41598-021-84096-x
  • 出版社:Springer Nature
  • 摘要:Abstract Streptococci are associated with dental plaque formation as the early-colonizing bacteria that adhere to titanium (CpTi) and zirconia (TZP) implant abutment surfaces. Effective prevention of peri-implantitis may be possible by removing streptococci as target. This study aimed to evaluate the effects of 2% NaF on the prevention of streptococcal adhesion to CpTi and TZP. After immersion in 2% NaF for 90 min, surface characterization of mirror-polished CpTi and TZP disks were assesed using XPS, EPMA, and SEM. S. sanguinis , S. gordonii , and S. oralis were used as the streptococcal bacterial strains. After 24 h culture, bacterial adhesion was evaluated using an ATP-bioluminescent assay and SEM. In XPS, EPMA, and SEM analyses, fluoride was detected on the CpTi and TZP surfaces after 2% NaF immersion with no signs of localization, and no corrosion on the CpTi disks. Based on the adhesion assay, the adherences of S. sanguinis , S. gordonii , and S. oralis were significantly lower with NaF than without NaF in CpTi ( p  = 0.005, 0.001, and 0.001, respectively) and TZP ( p  = 0.003, 0.002, and 0.001). This was also confirmed by SEM. In conclusion, 2% NaF reduced the adhesion of streptococci to the CpTi and TZP surfaces.
  • 其他摘要:Abstract Streptococci are associated with dental plaque formation as the early-colonizing bacteria that adhere to titanium (CpTi) and zirconia (TZP) implant abutment surfaces. Effective prevention of peri-implantitis may be possible by removing streptococci as target. This study aimed to evaluate the effects of 2% NaF on the prevention of streptococcal adhesion to CpTi and TZP. After immersion in 2% NaF for 90 min, surface characterization of mirror-polished CpTi and TZP disks were assesed using XPS, EPMA, and SEM. S. sanguinis , S. gordonii , and S. oralis were used as the streptococcal bacterial strains. After 24 h culture, bacterial adhesion was evaluated using an ATP-bioluminescent assay and SEM. In XPS, EPMA, and SEM analyses, fluoride was detected on the CpTi and TZP surfaces after 2% NaF immersion with no signs of localization, and no corrosion on the CpTi disks. Based on the adhesion assay, the adherences of S. sanguinis , S. gordonii , and S. oralis were significantly lower with NaF than without NaF in CpTi ( p  = 0.005, 0.001, and 0.001, respectively) and TZP ( p  = 0.003, 0.002, and 0.001). This was also confirmed by SEM. In conclusion, 2% NaF reduced the adhesion of streptococci to the CpTi and TZP surfaces.
国家哲学社会科学文献中心版权所有