首页    期刊浏览 2024年09月21日 星期六
登录注册

文章基本信息

  • 标题:Airspace Dimension Assessment (AiDA) by inhaled nanoparticles: benchmarking with hyperpolarised 129Xe diffusion-weighted lung MRI
  • 本地全文:下载
  • 作者:Madeleine Petersson-Sjögren ; Ho-Fung Chan ; Guilhem J. Collier
  • 期刊名称:Scientific Reports
  • 电子版ISSN:2045-2322
  • 出版年度:2021
  • 卷号:11
  • 期号:1
  • 页码:4721
  • DOI:10.1038/s41598-021-83975-7
  • 出版社:Springer Nature
  • 摘要:Abstract Enlargements of distal airspaces can indicate pathological changes in the lung, but accessible and precise techniques able to measure these regions are lacking. Airspace Dimension Assessment with inhaled nanoparticles (AiDA) is a new method developed for in vivo measurement of distal airspace dimensions. The aim of this study was to benchmark the AiDA method against quantitative measurements of distal airspaces from hyperpolarised 129 Xe diffusion-weighted (DW)-lung magnetic resonance imaging (MRI). AiDA and 129 Xe DW-MRI measurements were performed in 23 healthy volunteers who spanned an age range of 23–70 years. The relationship between the 129 Xe DW-MRI and AiDA metrics was tested using Spearman’s rank correlation coefficient. Significant correlations were observed between AiDA distal airspace radius ( r AiDA ) and mean 129 Xe apparent diffusion coefficient (ADC) (p < 0.005), distributed diffusivity coefficient ( DDC ) (p < 0.001) and distal airspace dimension ( Lm D ) (p < 0.001). A mean bias of − 1.2 µm towards r AiDA was observed between 129 Xe Lm D and r AiDA , indicating that r AiDA is a measure of distal airspace dimension. The AiDA R 0 intercept correlated with MRI 129 Xe α (p = 0.02), a marker of distal airspace heterogeneity. This study demonstrates that AiDA has potential to characterize the distal airspace microstructures and may serve as an alternative method for clinical examination of the lungs.
  • 其他摘要:Abstract Enlargements of distal airspaces can indicate pathological changes in the lung, but accessible and precise techniques able to measure these regions are lacking. Airspace Dimension Assessment with inhaled nanoparticles (AiDA) is a new method developed for in vivo measurement of distal airspace dimensions. The aim of this study was to benchmark the AiDA method against quantitative measurements of distal airspaces from hyperpolarised 129 Xe diffusion-weighted (DW)-lung magnetic resonance imaging (MRI). AiDA and 129 Xe DW-MRI measurements were performed in 23 healthy volunteers who spanned an age range of 23–70 years. The relationship between the 129 Xe DW-MRI and AiDA metrics was tested using Spearman’s rank correlation coefficient. Significant correlations were observed between AiDA distal airspace radius ( r AiDA ) and mean 129 Xe apparent diffusion coefficient (ADC) (p < 0.005), distributed diffusivity coefficient ( DDC ) (p < 0.001) and distal airspace dimension ( Lm D ) (p < 0.001). A mean bias of − 1.2 µm towards r AiDA was observed between 129 Xe Lm D and r AiDA , indicating that r AiDA is a measure of distal airspace dimension. The AiDA R 0 intercept correlated with MRI 129 Xe α (p = 0.02), a marker of distal airspace heterogeneity. This study demonstrates that AiDA has potential to characterize the distal airspace microstructures and may serve as an alternative method for clinical examination of the lungs.
国家哲学社会科学文献中心版权所有