首页    期刊浏览 2025年02月22日 星期六
登录注册

文章基本信息

  • 标题:Use of catheter with 2-methacryloyloxyethyl phosphorylcholine polymer coating is associated with long-term availability of central venous port
  • 本地全文:下载
  • 作者:Yuuki Iida ; Kumiko Hongo ; Takanobu Onoda
  • 期刊名称:Scientific Reports
  • 电子版ISSN:2045-2322
  • 出版年度:2021
  • 卷号:11
  • 期号:1
  • 页码:5385
  • DOI:10.1038/s41598-021-84885-4
  • 出版社:Springer Nature
  • 摘要:Abstract Central venous port (CVP) is a widely used totally implantable venous access device. Recognition of risks associated with CVP-related complications is clinically important for safe, reliable, and long-term intravenous access. We therefore investigated factors associated with CVP infection and evulsion, including the device type. A total of 308 consecutive patients with initial CVP implantation between January 2011 and December 2017 were retrospectively reviewed, and the association of clinical features with CVP-related complications were analyzed. Intraoperative and postoperative complications occurred in 11 (3.6%) and 39 (12.7%) patients, respectively. The overall rate of CVP availability at six months was 91.4%. Malignancy and 2-Methacryloyloxyethyl phosphorylcholine (MPC) polymer-coated catheter use were negatively associated with the incidence of CVP infections. Accordingly, malignancy and MPC polymer-coated catheter use were independent predictors for lower CVP evulsion rate (odds ratio, 0.23 and 0.18, respectively). Furthermore, both factors were significantly associated with longer CVP availability (hazard ratio, 0.24 and 0.27, respectively). This retrospective study identified factors associated with CVP-related complications and long-term CVP availability. Notably, MPC polymer-coated catheter use was significantly associated with a lower rate of CVP infection and longer CVP availability, suggesting the preventive effect of MPC coating on CVP infection.
  • 其他摘要:Abstract Central venous port (CVP) is a widely used totally implantable venous access device. Recognition of risks associated with CVP-related complications is clinically important for safe, reliable, and long-term intravenous access. We therefore investigated factors associated with CVP infection and evulsion, including the device type. A total of 308 consecutive patients with initial CVP implantation between January 2011 and December 2017 were retrospectively reviewed, and the association of clinical features with CVP-related complications were analyzed. Intraoperative and postoperative complications occurred in 11 (3.6%) and 39 (12.7%) patients, respectively. The overall rate of CVP availability at six months was 91.4%. Malignancy and 2-Methacryloyloxyethyl phosphorylcholine (MPC) polymer-coated catheter use were negatively associated with the incidence of CVP infections. Accordingly, malignancy and MPC polymer-coated catheter use were independent predictors for lower CVP evulsion rate (odds ratio, 0.23 and 0.18, respectively). Furthermore, both factors were significantly associated with longer CVP availability (hazard ratio, 0.24 and 0.27, respectively). This retrospective study identified factors associated with CVP-related complications and long-term CVP availability. Notably, MPC polymer-coated catheter use was significantly associated with a lower rate of CVP infection and longer CVP availability, suggesting the preventive effect of MPC coating on CVP infection.
国家哲学社会科学文献中心版权所有