摘要:The establishment of a microwave digestion method with the advantages of simple operation and complete digestion to process samples has shown that, high sensitivity, wide linear dynamic range, good precision, fast analysis speed and many other advantages of ICP-AES technology for rapid determination of tricalcium phosphate in bone china. Through the use of different P2O5 content of phosphate rock and kaolin national standard material configuration standard working solution for matrix matching to eliminate matrix interference, the microwave digestion sample processing condition selection, coexisting ion interference, method precision, accuracy, and detection limit tests were carried out. The results showed that the detection limit of the newly established method for tricalcium phosphate is 0.011mg.L-1; the HCl-HNO3-HF-H2O2 mixed acid decomposition system dissolves the best samples; the interference of the test results through the matrix matching coexisting ion pair is small; The relative standard deviation (RSD) is 1.08%~4.64%, and the recovery rate of standard addition is 92.4%~107.9%. The established method has high accuracy and precision; the bone china samples are analyzed and compared with the conventional digestion national standard method The t test method is used to prove that the two methods are not significantly different from the test results.
其他摘要:The establishment of a microwave digestion method with the advantages of simple operation and complete digestion to process samples has shown that, high sensitivity, wide linear dynamic range, good precision, fast analysis speed and many other advantages of ICP-AES technology for rapid determination of tricalcium phosphate in bone china. Through the use of different P2O5 content of phosphate rock and kaolin national standard material configuration standard working solution for matrix matching to eliminate matrix interference, the microwave digestion sample processing condition selection, coexisting ion interference, method precision, accuracy, and detection limit tests were carried out. The results showed that the detection limit of the newly established method for tricalcium phosphate is 0.011mg.L-1; the HCl-HNO3-HF-H2O2 mixed acid decomposition system dissolves the best samples; the interference of the test results through the matrix matching coexisting ion pair is small; The relative standard deviation (RSD) is 1.08%~4.64%, and the recovery rate of standard addition is 92.4%~107.9%. The established method has high accuracy and precision; the bone china samples are analyzed and compared with the conventional digestion national standard method The t test method is used to prove that the two methods are not significantly different from the test results.