期刊名称:Chemical Industry and Chemical Engineering Quarterly
印刷版ISSN:1451-9372
出版年度:2012
卷号:18
期号:1
页码:11-18
DOI:10.2298/CICEQ110625041S
出版社:Association of the Chemical Engineers
摘要:Pool boiling heat transfer coefficient of monoethylene glycol (MEG), diethylene glycol (DEG) and water ternary mixtures has been experimentally measured up to heat flux 114 kW/m2 at various volumetric concentrations of MEG and DEG. As expected, heat transfer coefficient was strongly taken as a direct function of heat flux. Existing well-known correlations are shown to be unable to predict the acceptable values for the tested ternary mixtures, particularly at different concentrations of MEG and DEG. Furthermore, a new modified correlation is developed on the basis of the Stephan - Preußer correlation that predicts the values of heat transfer coefficients with absolute average error of about 7% that is reasonable and acceptable values in compare to other existing correlations.