期刊名称:Journal of the Korean Ophthalmological Society
印刷版ISSN:0378-6471
出版年度:2021
卷号:62
期号:3
页码:295-299
DOI:10.3341/jkos.2021.62.3.295
出版社:The Korean Ophthalmological Society
摘要:Purpose To seek Pearson correlations of tear film osmolarity measured by the I-PEN ® (I-MED Pharma Inc., Dollard-des-Ormeaux, Canada) with Schirmer test result, tear break-up time, and Ocular Surface Disease Index score in patients with mild dry eye syndrome. Methods Patients with mild dry eye syndrome were divided into two groups according to Ocular Staining Score: group 1 (50 patients; 67 eyes) and group 2 (59 patients; 91 eyes), 90 patients and 158 eyes in total. The above mentioned correlations were derived. Results No significant correlations were observed between tear film osmolarity and Schirmer test result (r < -0.01, p = 0.97), tear break-up time (r = 0.05, p = 0.54), or Ocular Surface Disease Index score (r = 0.03, p = 0.76). When the two groups were compared, the Ocular Surface Disease Index score significantly differed between groups ( p < 0.01), whereas the Schirmer test result ( p = 0.31), tear break-up time ( p = 0.11), and tear film osmolarity ( p = 0.12) did not. Conclusions No significant correlations were found between tear film osmolarity and other dry eye indicators in patients with mild dry eye syndrome. The diagnostic utility of tear film osmolarity in patients with moderate dry eye syndrome is should be evaluated.