期刊名称:Journal of the Korean Ophthalmological Society
印刷版ISSN:0378-6471
出版年度:2021
卷号:62
期号:5
页码:605-611
DOI:10.3341/jkos.2021.62.5.605
出版社:The Korean Ophthalmological Society
摘要:Purpose We compared clinical outcomes including recurrence rate between amniotic membrane transplantation (AMT) and conjunctival autograft using fibrin glue and minimal conjunctival sutures for pterygium surgery. Methods We retrospectively analyzed 217 eyes of 198 patients with pterygia who underwent surgery from May 2016 to December 2019. Pterygium excision was performed with conjunctival autograft or AMT, using fibrin glue with both. Recurrence rates and complications were evaluated between the two groups. Results Postoperative recurrences were noted in one of 185 eyes (0.5%) in the conjunctival autograft group, and in six of 32 eyes (18.8%) in the AMT group. The recurrence rate was significantly lower in the conjunctival autograft group ( p < 0.001). Logistic regression analysis revealed that conjunctival autograft was associated with a significantly lower risk of pterygium recurrence compared to AMT (odds ratio, 0.023; 95% confidence interval, 0.003-0.206; p = 0.001). No ocular complication was noted in both groups during follow-up. Conclusions Pterygium excision with conjunctival autograft using fibrin glue was more effective in preventing recurrence compared to AMT.