首页    期刊浏览 2024年10月07日 星期一
登录注册

文章基本信息

  • 标题:Flecainide overdose – support using an intra-aortic balloon pump
  • 本地全文:下载
  • 作者:Jonathan Timperley ; Andrew RJ Mitchell ; Peter D Brown
  • 期刊名称:BMC Emergency Medicine
  • 印刷版ISSN:1471-227X
  • 电子版ISSN:1471-227X
  • 出版年度:2005
  • 卷号:5
  • 期号:1
  • 页码:10
  • DOI:10.1186/1471-227X-5-10
  • 语种:English
  • 出版社:BioMed Central
  • 摘要:

    Background

    Flecainide is an antiarrhythmic agent which is being used increasingly for the management of super-ventricular arrhythmias. Overdose with flecainide is frequently fatal with mortality reported as high as 22% due to arrhythmias, myocardial depression and conduction defects leading to electro-mechanical dissociation and asytole. Supportive measures are often required during the case and previously have included inotropes, extracorporeal membrane oxygenation and cardiopulmonary bypass.

    Case presentation

    A 47 year old lady presented to the emergency department with a four hour history of severe central chest pain. Her ECG showed atrial fibrillation and broad QRS complexes with a sine wave appearance. She had a past history of paroxysmal atrial fibrillation and significant psychiatric history. Following thrombolysis for a presumed myocardial infarction she developed cardiogenic shock with severely impaired left ventricular function. An intra-aortic balloon pump was inserted and coronary angiography demonstrated normal coronary arteries. With inotropic support she improved over 48 hours, with both her QRS duration and left ventricular function returning to normal. Biochemical testing following her discharge demonstrated significantly elevated levels of flecainide.

    Conclusion

    The use of an intra-aortic balloon pump is a useful supportive measure during the acute phase of flecainide overdose associated with severe myocardial depression.

国家哲学社会科学文献中心版权所有