首页    期刊浏览 2024年11月25日 星期一
登录注册

文章基本信息

  • 标题:Pharmacokinetic-Pharmacodynamic modeling of the analgesic effect of bupredermTM, in mice
  • 本地全文:下载
  • 作者:Min-Hyuk Yun ; Seung-Wei Jeong ; Chaul-Min Pai
  • 期刊名称:Health
  • 印刷版ISSN:1949-4998
  • 电子版ISSN:1949-5005
  • 出版年度:2010
  • 卷号:2
  • 期号:8
  • 页码:824-831
  • DOI:10.4236/health.2010.28124
  • 出版社:Scientific Research Publishing
  • 摘要:Purpose: BupredermTM-Buprenorphine transdermal delivery system (BTDS) was developed for the treatment of post-operative and chronic pains. This study examined the relationship between the plasma concentration of buprenorphine and its analgesic effect (tail flick test) in order to assess the usefulness of pharmacokinetic-pharmacodynamic (PK-PD) modeling in describing this relationship. Methods: After patch application, plasma concentrations of bu- prenorphine in mice were measured for 72 hours with a validated LC/MS/MS system, and the analgesic effects were assessed by tail flick test for the period of 24 hours. A modified two- compartment open model was used to explain the PK properties of BTDS, and the PD model was characterized by slow receptor binding. Results: The peak buprenorphine level in plasma was achieved at 1-24 h and the effective therapeutic drug concentration was maintained for 72 hours. BupredermTM induced prolongation of tail-flick latency in a dose and time dependent manner. Maximum analgesic effect was attained at 3-6 h and was maintained for 24 h after patch application. Counter-clockwise hysteresis between the plasma concentration and the analgesic efficacy of BTDS was observed after BupredermTM application, indicating there was a delay between plasma concentrations and the effect observed. From the developed PK-PD model, Kd values (0.69-0.82 nM) that were derived from the pharmacodynamic parameters (Kon and Koff) are similar to the reported values (Kd = 0.76 ± 0.14 nM). Good agreement between the predicted and observed values was noted for the rate of change in analgesic effect data (R2 = 0.822, 0.852 and 0.774 for 0.24, 0.8 and 2.4 mg/patch, respectively). Conclusions: The established PK- PD model successfully described the relationship between plasma concentration of buprenorphine and its analgesic efficacy measured by the tail flick test. Our model might be useful in estimation and prediction of onset, magnitude and time course of concentration and pharmacological effects of BTDS and will be useful to simulate PK-PD profiles with clinical regimens.
  • 关键词:Pharmacokinetic-Pharmacodynamic Modeling; BupredermTM; Buprenorphine; Transdermal System; Slow Receptor-Binding Model
国家哲学社会科学文献中心版权所有