期刊名称:Proceedings of the National Academy of Sciences
印刷版ISSN:0027-8424
电子版ISSN:1091-6490
出版年度:2005
卷号:102
期号:48
页码:17278-17283
DOI:10.1073/pnas.0508821102
语种:English
出版社:The National Academy of Sciences of the United States of America
摘要:Quantitative protein bioanalysis in complex biological fluids presents considerable challenges in biological studies and disease diagnosis. The major obstacles are the background signals from both the probe and the biological fluids where the proteins reside. We have molecularly engineered light-switching excimer aptamer probes for rapid and sensitive detection of a biomarker protein, platelet-derived growth factor (PDGF). Labeled with one pyrene at each end, the aptamer switches its fluorescence emission from {approx}400 nm (pyrene monomer) to 485 nm (pyrene excimer) upon PDGF binding. This fluorescence wavelength change from monomer to excimer emission is a result of aptamer conformation rearrangement induced by target binding. The excimer probe is able to effectively detect picomolar PDGF in homogeneous solutions. Because the excimer has a much longer fluorescence lifetime ({approx}40 ns) than that of the background ({approx}5 ns), time-resolved measurements were used to eliminate the biological background. We thus were able to detect PDGF in a cell sample quantitatively without any sample pretreatment. This molecular engineering strategy can be used to develop other aptamer probes for protein monitoring. Combined with lifetime-based measurements and molecular engineering, light-switching excimer aptamer probes hold great potential in protein analysis for biomedical studies.