期刊名称:Analele Universităţii din Craiova. Seria Geografie
印刷版ISSN:1224-4112
电子版ISSN:2069-6191
出版年度:2008
卷号:11
出版社:Universitatea din Craiova
摘要:In order to carry out the foundation of WEST GATE MALL establishment, because the phreatic water level proved to be 1-2 m higher than the geotechnical study preestablished one, it was necessary its temporary lowering. For this problem to be solved we have suggested a double series of drillings with submersible pumps and between these foundations could be safely executed. Thus, according to our calculations presented in the article, the distance between the series of drillings has been established at 20 m, the dislevelment in the drillings reaching 4 m.