首页    期刊浏览 2024年12月03日 星期二
登录注册

文章基本信息

  • 标题:Vapour retarders in wood frame walls and their effect on the drying capability
  • 本地全文:下载
  • 作者:Stig Geving ; Jonas Holme
  • 期刊名称:Frontiers of Architectural Research
  • 印刷版ISSN:2095-2635
  • 出版年度:2013
  • 卷号:2
  • 期号:1
  • 页码:1-8
  • DOI:10.1016/j.foar.2012.12.003
  • 出版社:Elsevier
  • 摘要:Wood frame walls typically need a vapour barrier at the warm side to avoid interstitial condensation due to vapour diffusion and air leakages from the interior. A more vapour open material than the traditional vapour barriers, here called vapour retarder, could allow condensed moisture, built-in-moisture or moisture from minor leakages to dry to the interior in addition to the outward drying. The application of permeable vapour retarders in wood frame walls have been investigated in this study by the use of a hygrothermal simulation tool. A traditional wood frame wall usually has good drying possibilities to the exterior. If a vapour retarder should have an effect on the total drying, it must not be too vapour tight. The purpose of this study was to find some threshold value for the maximum vapour resistance of a vapour retarder—when a requirement is that it should have a relatively large effect of the total drying of the wall. The increased risk for condensation as the vapour resistance decreases has however not been investigated in this study. In general it was found that permeable vapour barriers have relatively little effect on the total drying of ordinary wood frame walls in a Nordic climate.
  • 关键词:Vapour barrier ; Vapour retarder ; Wood frame wall ; Drying ; Moisture
国家哲学社会科学文献中心版权所有